Biolight M Series 5-pin Finger Clip SpO2 Sensor PN:15-100-0010 REF:A0212-SA125PV

Announcer: PMR Med Release Time:2023-02-24

Biolight Finger SpO2 Sensor 15-100-0010

Biolight M Series 5-pin Finger Clip SpO2 Sensor PN:15-100-0010 REF:A0212-SA125PV

Biolight M series BLT M69 5 pin  Finger SpO2 Sensor PN15-100-0010  REFA0212-SA125PV - 1.jpg

Brief Description

Biolight Finger SpO2 Sensor is a sensor used to detect SpO2 for patients. It is a Clip-style design, number 15-100-0010 / A0212-SA125PV. The Biolight Finger SpO2 Sensor 15-100-0010 is used on the patient's finger for measurement. The probe of the sensor is mainly clamped on the patient's non-dominant finger. In special cases, it can also be clamped on other parts for monitoring. The Biolight Finger SpO2 Sensor 15-100-0010 can be used in hospitals, homes, medical institutions and various medical care environments. This product does not contain natural latex and is suitable for most people.



Specification


Brand

Biolight

Part Number

15-100-0010

REF

A0212-SA125PV

Product Category

SpO2

Product Type

Sensor

Applicable Site

Finger

Number of Pins

5

Sensor Type

Clip 




Precautions

All sensors and cables are designed to work with specific monitors. Before use, monitor, lead wires, and sensors should be checked for compatibility, failure to do so could result in degraded performance and/or patient injury.

The monitoring site must be checked frequently or as clinically required to ensure that the adhesive is firmly adhered, blood circulation is good, the skin is intact and the sensor is properly optically aligned.

Caution should be exercised when using the sensor in hypoperfused patients and it is important to move the sensor frequently to avoid skin erosion and compressive tissue necrosis in the patient. In hypoperfused patients, the monitoring site should be checked at least hourly and the sensor should be moved if signs of tissue ischemia are present.

Do not use adhesive tape to fix the sensor and the detection site, otherwise the blood flow may be blocked, resulting in inaccurate readings. Using excess tape can also damage the skin and/or cause pressure necrosis, or damage the sensor.



Detailed Photos

 

 Biolight M series BLT M69 5 pin  Finger SpO2 Sensor PN15-100-0010  REFA0212-SA125PV - 7.jpg








Thanks for your time, if you are interested in Biolight M Series 5-pin Finger Clip SpO2 Sensor PN:15-100-0010 REF:A0212-SA125PV, or have any suggestions for us, please feel free to contact us. We will reply you within 12 hours, wish you a happy life.









Tags: , , ,

Copyright statement:If not specified, the articles on this site are all PMR Med originals. Please indicate the source and attach the link to the Biolight M Series 5-pin Finger Clip SpO2 Sensor PN:15-100-0010 REF:A0212-SA125PV article for reprinting.



Send your inquiry directly to us







CONTACT DETAILS


China Patient Monitor Repair Company

Contact Person:Katie Lee

Tel:8618879071075

Fax:86-188-790-71075